About Us
Michigan’s Premier Environmental Microbiology Laboratory
State-of-the-Art Technology. ELISA-based or molecular-based next day test results.
Thomas Krueger, President
Summit Laboratory, LLC
Founded in 1999, Summit Laboratory brings the “Fusion of Science and Service” to the Great Lakes region. At Summit, we continually strive for excellence through our exacting standards in scientific analysis and quality, as well as our dedication to personalized attention and competitive prices.
Summit Laboratory is the first organization in the U.S. to receive accreditation for Environmental Swabbing from the A2LA. This is in addition to two other accreditations recently earned for Listeria spp. Testing and Salmonella spp. testing from Solus. Read the full story.
As an A2LA certified ISO 17025 accredited* laboratory, Summit is proven to have a world-class quality management system. Partnering with us means you’ll always receive data and documentation considered traceable and more defendable.
And because the ISO 17025 accreditation requires continual improvement through regular internal audits and adherence to the latest scientific and technological advances, you can rest assured that your samples are always at the right certified laboratory.
*See our Scope for a list of accreditations
We Strive for Excellence Every Day
Efficient, affordable, quality analysis is only the beginning of the services Summit Laboratory provides. We pride ourselves on the relationships we establish and grow with our customers. We begin by working with you to identify your testing requirements and follow up with an explanation of the results of our analysis. We put the needs of our customers first and are committed to your complete satisfaction.
Our Scientists
We are a team that is truly passionate about what we do. Each of our scientists holds a degree in their area of expertise and brings years of experience and continuing education into each analysis. While that’s not guaranteed with all testing laboratories, we think it should be. Because at Summit, we understand a crucial part of quality analysis is accurate interpretation of the data. We provide these services with state of the art equipment that allows expedited results at prices competitive with industry standards.
Summit Laboratory specializes in servicing the following areas:
- Food Safety
- Facility and Equipment Environmental Monitoring and Training
- Water Testing
- Mold Testing
- Pharmaceutical Testing
- Third-party Product Testing and Claims Verification
QUALITY ASSURANCE PRACTICES
Summit Laboratory’s philosophy puts customers first. This means we must adhere to strict laboratory testing techniques and protocols that ensure correct and reliable data. To put it less scientifically, at Summit, we pay the utmost attention to quality control methods that enable us to not only obtain our certified laboratory status, but to stay abreast of changing regulations and methods of data collection as well.
QUALITY LABORATORY PRACTICES:
- Usage of only AOAC, FDA & USDA standard certified methods
- All samples are analyzed by professional biologists
- Certified quantitative and qualitative standards are routinely tested with samples
- Disposable pipette and plating equipment is used to help eliminate cross contamination
- Documentation of laboratory cleaning and sanitizing procedures
- Inter-laboratory quality assurance ensures precision and accuracy of routine data
- Continued employee education and training via college classes (Including classes at McCrone Research Institute), workshops, seminars, webinars, and conferences
CERTIFIED TEST METHODS
- American Public Health Association Standard Methods for examination of water and wastewater
- American Public Health Association Standard Methods for the Examination of Dairy Products
- FDA Bacteriological Analytical Manual
- Official Methods of Analysis of AOAC INTERNATIONAL
- Compendium of Methods for the Microbiological Examination of Foods
- USP The Official Compendia of Standards
- ISO and IEC Guide 25
- Food Analysis by Nielsen
- ANSI/IICRC S520
- Bioaerosols: Assessment and Control, ACGIH
- U.S.D.A. Microbiological Lab Manual
- The Practitioners Approach to Indoor Air Quality Investigations
- The Particle Atlas
ACCREDITATIONS
KENTWOOD LABORATORY
Summit A2LA ISO 17025 cert and scope valid to May 31, 2027
SUMMIT LABORATORY LLC
3351 36th Street SE
Kentwood, MI 49512
Thomas Krueger
Phone: 616.245.3818
tomk@summitlaboratory.com
BIOLOGICAL
Valid To: May 31, 2027 Certificate Number 3136.01
In recognition of the successful completion of the A2LA evaluation process (including an assessment of the laboratory’s compliance with the A2LA Food Testing Program Requirements, containing the 2017 AOAC International Accreditation Guidelines for Laboratories Performing Microbiological and Chemical Analyses of Foods, Feeds, and Pharmaceutical Testing), accreditation is granted to this laboratory to perform the following tests on food products and environmental swabs:
| Test: | Test Method: |
|---|---|
| Neogen Molecular Detection Assay 2 – Campylobacter spp. | AOAC 111803 |
| Neogen Molecular Detection Assay 2 – Cronobacter spp. | AOAC 2018.01 |
| Neogen Molecular Detection Assay 2 – Escherichia coli O157:H7 | AOAC 2017.01 |
| Neogen Molecular Detection Assay 2 – Listeria monocytogenes | AOAC 2016.08 |
| Neogen Molecular Detection Assay 2 – Listeria spp. | AOAC2016.07 |
| Neogen Molecular Detection Assay 2 – Salmonella | AOAC 2016.01 |
| Neogen Molecular Detection Assay 2- STEC (stx & eae) | AOAC 071902 |
| Neogen Petrifilm Aerobic Count Plate | AOAC 990.12 |
| Neogen Petrifilm Rapid Aerobic Plate count (24 hour) | AOAC 2015.13 |
| Neogen Petrifilm Coliform/ E. coli Count Plate | AOAC 991.14 |
| Neogen Petrifilm Rapid Escherichia coli I Total Coliform (18-24 hour) | AOAC 2018.13 |
| Neogen Petrifilm Enterobacteriaceae | AOAC 2003.01 and CM 2001 Ch. 8 |
| Neogen Petrifilm Lactic Acid Bacteria | AOAC 041701 |
| Neogen Petrifilm Staphylococcus aureus Express Count Plate | AOAC 2003.07 |
| Neogen Petrifilm Yeast and Mold Count Plate (5 day) | AOAC 997.02 |
| Neogen Petrifilm Rapid Yeast and Mold Count Plate (3 day) | AOAC 2014.05 |
| MicroFast film Rapid Aerobic Count Plate (24 hour) | AOAC 032103 |
| MicroFast film Coliform Count Plate (24 hour) | AOAC 102102 |
| MicroFast film Coliform / E. coli Count Plate (24 hour) | AOAC 102103 |
| MicroFast film Staphylococcus aureus Count Plate (24 hour) | AOAC 122102 |
| MicroFast film Yeast and Mold Count Plate (3 day) | AOAC 122101 |
| Chromogenic Agar – E.coli O157:H7 | AOAC Cert. 06070 I |
| Chromogenic Agar – L. monocytogenes | AOAC Cert. 030406 |
| Chromogenic Agar – Salmonella | AOAC Cert. 050701 |
| Neogen Allergen I Veratox® for Gliadin R5 – Gluten | AOAC 061201 |
| Isolation of Listeria spp. and Listeria monocytogenes for Confirmation (Modified) | FDA BAM Chapter 10 Method |
| Isolation of Salmonella spp. for Confirmation (Modified) | FDA BAM Chapter 5 Method |
| Environmental swabbing (collection and analyzing) | ISO 18593 |
| Solus One Listeria | AOAC 051802 |
| Solus One Salmonella | AOAC 101801 |
This accreditation covers testing performed at the main laboratory as well as the satellite laboratory listed below. (A2LA Cert. No. 3136.01) 05/31/2025
HART LABORATORY
Summit A2LA ISO 17025 cert and scope valid to May 31, 2027
SUMMIT LABORATORY LLC
1535 Industrial Park Dr.
Hart, MI 49420
Thomas Krueger
Phone: 231.873.1432, x227
tomk@summitlaboratory.com
BIOLOGICAL
Valid To: May 31, 2027 Certificate Number 3136.01
| Test: | Test Method: |
|---|---|
| Neogen Molecular Detection Assay 2 – Escherichia coli O157:H7 | AOAC 2017.01 |
| Neogen Molecular Detection Assay 2 – Listeria monocytogenes | AOAC 2016.08 |
| Neogen Molecular Detection Assay 2 – Listeria spp. | AOAC 2016.07 |
| Neogen Molecular Detection Assay 2 – Salmonella | AOAC 2016.01 |
| Neogen Molecular Detection Assay 2 – STEC (stx & eae) | AOAC 071902 |
| Neogen Petrifilm Aerobic Count Plate | AOAC 990.12 |
| Neogen Petrifilm Rapid Aerobic Plate count (24 hour) | AOAC 2015.13 |
| Neogen Petrifilm Coliform/ E. coli Count Plate | AOAC 991.14 |
| Neogen Petrifilm Rapid Escherichia coli I Total Coliform (18-24 hour) | AOAC 2018.13 |
| Neogen Petrifilm Enterobacteriaceae | AOAC 2003.01 and CM 2001 Ch. 8 |
| Neogen Petrifilm Lactic Acid Bacteria | AOAC 041701 |
| Neogen Petrifilm S. aureus Express Count Plate | AOAC 2003.07 |
| Neogen Petrifilm Yeast and Mold Count Plate (5 day) | AOAC 997.02 |
| Neogen Petrifilm Rapid Yeast and Mold Count Plate (3 day) | AOAC 2014.05 |
| MicroFast film Rapid Aerobic Count Plate (24 hour) | AOAC 032103 |
| MicroFast film Coliform Count Plate (24 hour) | AOAC 102102 |
| MicroFast film Coliform/ E. coli Count Plate (24 hour) | AOAC 102103 |
| MicroFast film Staphylococcus aureus Count Plate (24 hour) | AOAC 122102 |
| MicroFast film Yeast and Mold Count Plate (3 day) | AOAC 122101 |
| Chromogenic Agar – E. coli O157:H7 | AOAC Cert. 060701 |
| Chromogenic Agar – L. monocytogenes | AOAC Cert. 030406 |
|
Chromogenic Agar – Salmonella |
AOAC Cert. 050701 |
|
Environmental swabbing (collection and analyzing) |
ISO 18593 |
|
Solus One Listeria |
AOAC 051802 |
|
Solus One Salmonella |
AOAC 101801 |
(A2LA Cert. No. 3136.01) 05/31/2025
AFFILIATIONS & MEMBERSHIPS
CERTIFICATIONS
- A2LA Certified/IS0 17025 accredited*
- HACCP certified managers on staff
- SQF 2000 certified practitioners
- Certified microbial investigators
- ACAC certified microbial consultants
- State of Michigan (MDEQ) certified for drinking and irrigation water analysis
- State of Michigan Department of Environmental Quality Remediation & Redevelopment Division certified for: total coliform, E. coli (See Certification), nitrate nitrogen (See Certification)
- Certified mold investigators and mold consultants
- McCrone Research Institute trained in: Indoor Air Quality:
- Fungal Spore Identification
- Forensic Dust Analysis